BS EN 12350-8 PDF

BS EN BRITISH STANDARD National foreword This British Standard is the UK implementation of EN This publication does not. Find the most up-to-date version of BS EN at Engineering PREN Draft BS EN Testing fresh concrete. Part 8: Self- compacting concrete – Slump-flow test.

Author: Bami Akinonris
Country: Mali
Language: English (Spanish)
Genre: Relationship
Published (Last): 24 April 2018
Pages: 479
PDF File Size: 17.24 Mb
ePub File Size: 20.58 Mb
ISBN: 732-1-46995-835-8
Downloads: 56989
Price: Free* [*Free Regsitration Required]
Uploader: Mokazahn

Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. Lift the cone vertically in 1 s to 3 s in one movement without interfering with the flow of concrete.

Take precautions bx avoid dry cement entering the eyes, mouth and nose whilst mixing concrete. When the cone is withdrawn upwards the time from commencing upward movement of the cone to when the concrete has flowed to a diameter of mm is measured; this is the t time.

It is based on the slump test described in EN Enn test is not suitable when the maximum size of the aggregate exceeds 40 mm.

Proceed to Checkout Continue Shopping. For further information, email bsmusales.

Your Alert Profile lists the documents that will be monitored. Please first log in with a verified email before subscribing to alerts. This standard is one of a series concerned with testing bd concrete. Find out more about British Standards by visiting our website at commercial publication and use. For dated references, only the edition cited applies. E measure the diameter of the flow spread at right angles to d to the nearest 10 mm and record as d to the nearest 10 mm.

  24C256 EEPROM PDF

Licences can cover as few or as many users as you wish. The deviation from flatness shall not exceed 3 mm at any point when a straight edge is placed 123350-8 opposing sides and corners. Slump-test 3 Principle The slump-flow and t time is used to assess the flowability and the flow rate of self-compacting concrete in the absence of obstructions.

Need more than one copy? Check the top surface for horizontality using the spirit level. If the document is revised or amended, you will be notified by email.

All lines to 123550-8 a maximum of 2,0 mm wide and 1,0 mm deep. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by Januaryand conflicting national standards shall be withdrawn at the latest by January We have no amendments or corrections for this standard.

123350-8 t time is a measure of the speed of flow and an indication of the relative viscosity of the self-compacting concrete.

  LG SV IG5A PDF

Standards Subscriptions from ANSI provides a money-saving, multi-user solution for accessing standards. NOTE The collar allows the test to be carried out by one person. The surface shall not be readily attacked by cement 123550-8 or be liable to rusting.

BS EN 12350-8:2010

Wash wet concrete off the skin immediately. Allow the filled cone to fn for not more than 30 s; during this time remove any spilled concrete from the baseplate. If the difference 1 2 between d and d is greater than 50 mm another sample shall be taken and the procedure repeated.

Users are responsible for its correct application.

BS EN – Testing fresh concrete. Self-compacting concrete. Slump-flow test

It is desirable, especially in the case of new constituents or new concrete compositions, to test the consistence of fresh SCC before casting in place. You may delete a document from your Alert Profile at any time.

E worldwide for CEN national Wn. The report may include: Clean the table and the cone and dampen immediately prior to testing, but keep free from excess moisture.